| SPECIFICATION |
UNITS / FEATURES |
MODELS
|
The SAL Saline Chlorinators and Chlorination
Systems consists of various modular units with variable chlorine production
capacities. |
| TYPE |
In-line - Commercial Hypochlorite Plant |
| NO. UNITS |
Plant can be designed to comfortably meet
chlorine production requirements with single rectifier/cell modular
units. If system back up is required or desirable, systems can be
designed to tolerate multiple cell shut-down without affecting the
rest of the system. |
| CHLORINE PRODUCTION |
From 50 grams per hour to 50 kilograms per
hour or greater. |
| SALT CONCENTRATION |
The system relies on the presence of salt
in the water, ranging from seawater concentrations (3.5%) to as little
as 5,500 ppm salt concentrations. |
WATER TREATMENT
VOLUME |
The pre-engineered range is designed to meet
the chlorine requirements of any water volume or water flow rate.
Where pre-engineered models are not suited to a particular application,
units are tailor designed. |
| RECTIFIER |
Designed to Australian Standards AS3108 &
AS2374. |
| Cabinet |
Thickness - 1.6mm |
| |
Finish - Powder coated zinc anneal steel
to 85 microns. |
| Power Supply |
Up to and including 330 grams/hr - Single
phase power supply. |
| > 330 rams/hour - 3 Phase power is required. |
| Single Phase |
3 Phase Rectification |
| Primary Input Voltage |
110-240V |
415V |
| RECTIFIER CONTROL |
- Transformers are tapped for world power
variation. |
| Equipment |
- Variable Chlorine Control |
| |
- Ammeter (conventional) |
| - Main Power On Switch |
| - Rectifier Power On Switch |
| - Primary & Secondary alarm |
| - Lamps displaying: Power On, Rectifier On,
Water Flow Fault, Temperature Alarm |
| Soft Start Up |
For maximum cell protection the unit is fitted
with thyristor controls, soft start auto voltage and amperage romping. |
| Cooling System |
Air or Fan cooled (on larger units). |
| ELECTRODE
CELL(S) |
Type - Monopolar, solid 1.6mm solid plate
electrodes. |
| Material |
Cathode - Solid Titanium plate. |
| Anode - Solid Titanium plate, coated with
SC6 industrial quality coatings. |
| Cell Cleaning |
Up to 330g/h Cl - Removal of cell and manual
acid cleaning with mild acid solution, facilitated by acid cleaning
chamber. |
| Above 330g/h Cl - Provide a semi-automatic,
manual valve operated acid wash system, incorporating pump, check
valves and acid tank. |
| Plumbing |
Pipes,
fittings and valves - Industrial grade heavy walled PVC or CPVC. Factory
tested to 400 kPa. Electrode Inspection facilitated by clear PVC inspection
portal in cell chamber. |
Minimum
Water Flow
|
The
electrode cells require minimum water flow rates to ensure efficient
heat transfer and maximum efficiency. Refer to Commercial Plant Specifications. |